{"id":6926,"date":"2025-01-08T08:47:14","date_gmt":"2025-01-08T07:47:14","guid":{"rendered":"https:\/\/www.bpmtc.ch\/materiels\/akta-go\/"},"modified":"2026-07-27T15:31:21","modified_gmt":"2026-07-27T13:31:21","slug":"akta-go","status":"publish","type":"portfolio","link":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/","title":{"rendered":"AKTA Go"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row wrap_container=&#8220;yes&#8220; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220;][vc_column width=&#8220;1\/2&#8243;][vc_single_image image=&#8220;6936&#8243; img_size=&#8220;full&#8220; css=&#8220;.vc_custom_1782740974152{padding-bottom: 25px !important;}&#8220; el_class=&#8220;mb-3&#8243; css_params=&#8220;&#8220; label=&#8220;&#8220;][\/vc_column][vc_column width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;AKTA Go \u2013 Kompaktes Fl\u00fcssigkeitschromatographiesystem&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1775987711482{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Das AKTA go\u2122 ist ein kompaktes Fl\u00fcssigkeitschromatographiesystem, das von Cytiva f\u00fcr Routinereinigungen im Labor entwickelt wurde. Mit einem Durchflussbereich von bis zu 25 ml\/min und einem Betriebsdruck von bis zu 5 MPa deckt es den Gro\u00dfteil der Anforderungen in der Affinit\u00e4ts-, Gr\u00f6\u00dfenausschluss- oder Ionenaustauschchromatographie ab. Sein modularer Aufbau erm\u00f6glicht es, je nach Weiterentwicklung Ihrer Protokolle bis zu sechs optionale Komponenten hinzuzuf\u00fcgen, w\u00e4hrend es dank seiner Pumpe mit Titank\u00f6pfen und seines Mischers ohne bewegliche Teile nur wenig Wartung erfordert. Durch seine kompakte Bauweise ist es ein wertvoller Verb\u00fcndeter bei der Optimierung Ihres Labortischplatzes. Die Steuerung erfolgt \u00fcber die Software UNICORN\u2122 mit einer vereinfachten Benutzeroberfl\u00e4che und einer interaktiven Ansicht des Durchflusses Ihres Systems. BPM TechCare \u00fcbernimmt die vorbeugende und korrektive Wartung Ihres AKTA go in der Schweiz, um dessen langfristige Zuverl\u00e4ssigkeit zu gew\u00e4hrleisten.     &#8220; font_container=&#8220;tag:p|text_align:left|line_height:1.8em&#8220; use_theme_fonts=&#8220;yes&#8220; letter_spacing=&#8220;-0.015em&#8220; css=&#8220;.vc_custom_1782734990669{margin-bottom: 2.7rem !important;}&#8220; css_params=&#8220;&#8220;][\/vc_column][\/vc_row][vc_row wrap_container=&#8220;yes&#8220; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220; css=&#8220;.vc_custom_1736877412602{margin-bottom: 2.6rem !important;}&#8220;][vc_column width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;Maximale Effizienz bei minimalem Platzbedarf&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1774977983806{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Der AKTA Go wurde f\u00fcr Forscher entwickelt, die keine Kompromisse zwischen Leistung und Platzbedarf eingehen m\u00f6chten. Dank seiner kompakten Abmessungen (nur 335 \u00d7 464 mm) l\u00e4sst er sich problemlos in jedes Labor integrieren und bietet gleichzeitig die f\u00fcr einen intensiven Einsatz erforderliche Robustheit. &#8220; font_container=&#8220;tag:p|text_align:left|line_height:1.8em&#8220; use_theme_fonts=&#8220;yes&#8220; letter_spacing=&#8220;-0.015em&#8220; css=&#8220;.vc_custom_1775987733343{margin-bottom: 1.3rem !important;}&#8220; css_params=&#8220;&#8220;][vc_row_inner css=&#8220;.vc_custom_1775054888214{padding-top: 20px !important;padding-right: 10px !important;padding-bottom: 20px !important;padding-left: 10px !important;background-color: #ebebeb !important;}&#8220; css_params=&#8220;&#8220;][vc_column_inner][vc_custom_heading text=&#8220;Technische Daten&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1775054840139{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_column_text css=&#8220;&#8220; css_params=&#8220;&#8220; el_class=&#8220;mb-2&#8243;]<\/p>\n<table data-path-to-node=\"17\">\n<thead>\n<tr>\n<td><strong>Spezifikation<\/strong><\/td>\n<td><strong>Details<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span data-path-to-node=\"17,1,0,0\"><b data-path-to-node=\"17,1,0,0\" data-index-in-node=\"0\">Durchfluss<\/b><\/span><\/td>\n<td><span data-path-to-node=\"17,1,1,0\">Bis zu 25 ml\/min<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"17,2,0,0\"><b data-path-to-node=\"17,2,0,0\" data-index-in-node=\"0\">Maximaler Druck<\/b><\/span><\/td>\n<td><span data-path-to-node=\"17,2,1,0\">5 MPa (50 bar \/ 725 psi)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"17,3,0,0\"><b data-path-to-node=\"17,3,0,0\" data-index-in-node=\"0\">Steuerungssoftware<\/b><\/span><\/td>\n<td><span data-path-to-node=\"17,3,1,0\">UNICORN\u2122 7<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"17,4,0,0\"><b data-path-to-node=\"17,4,0,0\" data-index-in-node=\"0\">Abmessungen (L \u00d7 T \u00d7 H)<\/b><\/span><\/td>\n<td><span data-path-to-node=\"17,4,1,0\">335 \u00d7 464 \u00d7 476 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"17,5,0,0\"><b data-path-to-node=\"17,5,0,0\" data-index-in-node=\"0\">UV-Detektor<\/b><\/span><\/td>\n<td><span data-path-to-node=\"17,5,1,0\">Feste Wellenl\u00e4nge (280 nm)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"17,6,0,0\"><b data-path-to-node=\"17,6,0,0\" data-index-in-node=\"0\">Anzahl der Puffereing\u00e4nge<\/b><\/span><\/td>\n<td><span data-path-to-node=\"17,6,1,0\">2 Eing\u00e4nge A und 2 Eing\u00e4nge B<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner]<div class=\"porto-gallery has-ccols ccols-1 has-ccols-spacing ccols-sm-2 ccols-md-3 wpb_custom_0cd1f54877e50b1d688accb9c105d819 porto-gallery-masonry py-3\" data-plugin-masonry data-plugin-options=\"{&quot;layoutMode&quot;:&quot;masonry&quot;,&quot;itemSelector&quot;:&quot;figure&quot;,&quot;masonry&quot;:{&quot;columnWidth&quot;:&quot;figure&quot;},&quot;animationEngine&quot;:&quot;best-available&quot;,&quot;resizable&quot;:false}\"><figure><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp\" class=\"attachment-full size-full\" alt=\"\u00c4KTA Go de Cytiva, syst\u00e8me compact de chromatographie liquide FPLC pour la purification automatis\u00e9e de prot\u00e9ines en laboratoire de recherche et biotechnologie.\" srcset=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp 600w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06-400x400.webp 400w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06-560x560.webp 560w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06-367x367.webp 367w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><figure><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-01.webp\" class=\"attachment-full size-full\" alt=\"\u00c9quipement \u00c4KTA Go Cytiva compact et performant pour les applications de chromatographie liquide et de purification prot\u00e9ique automatis\u00e9e.\" srcset=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-01.webp 600w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-01-400x400.webp 400w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-01-560x560.webp 560w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-01-367x367.webp 367w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><figure><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-02.webp\" class=\"attachment-full size-full\" alt=\"Syst\u00e8me \u00c4KTA Go Cytiva en cours de purification de prot\u00e9ines gr\u00e2ce \u00e0 la chromatographie liquide automatis\u00e9e haute performance pour laboratoires scientifiques.\" srcset=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-02.webp 600w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-02-400x400.webp 400w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-02-560x560.webp 560w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-02-367x367.webp 367w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><figure><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-05.webp\" class=\"attachment-full size-full\" alt=\"Modules et vannes de l&#039;\u00c4KTA Go offrant une configuration flexible pour les applications de chromatographie liquide en laboratoire.\" srcset=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-05.webp 600w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-05-400x400.webp 400w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-05-560x560.webp 560w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-05-367x367.webp 367w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><figure><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-04.webp\" class=\"attachment-full size-full\" alt=\"Logiciel UNICORN pilotant l&#039;\u00c4KTA Go pour le contr\u00f4le des m\u00e9thodes de chromatographie et la purification reproductible des biomol\u00e9cule\" srcset=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-04.webp 600w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-04-400x400.webp 400w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-04-560x560.webp 560w, https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-04-367x367.webp 367w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure><\/div>[\/vc_column][vc_column width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;Die St\u00e4rken des Systems&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1774978005516{margin-bottom: 1.8rem !important;}&#8220; css_params=&#8220;&#8220;]<div class=\"porto-sicon-box  vc_custom_1775030791644  wpb_custom_a0a370c8295ee40fc7556ca4643d7f66 style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Intuitive Gestaltung<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"\">Ein einfaches Bedienfeld und die weltweit anerkannte UNICORN\u2122-Software sorgen f\u00fcr eine sofortige Einarbeitung.<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775049867418  wpb_custom_a0a370c8295ee40fc7556ca4643d7f66 style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Vielseitigkeit bei der Reinigung<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"\">Kompatibel mit einer breiten Palette an S\u00e4ulen und Harzen (HiTrap, HiPrep usw.) zur Aufreinigung von Antik\u00f6rpern, rekombinanten Proteinen und anderen Biomolek\u00fclen.<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775030810601  wpb_custom_a0a370c8295ee40fc7556ca4643d7f66 style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Integrierte Methodenunterst\u00fctzung<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"\">Vordefinierte Protokolle, um Zeit zu sparen und die Reproduzierbarkeit Ihrer Ergebnisse zu gew\u00e4hrleisten.<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775030819857  wpb_custom_a0a370c8295ee40fc7556ca4643d7f66 style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Einfachere Wartung<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"\">Direkter Zugriff auf Komponenten und Software-Diagnosefunktionen zur Minimierung von Ausfallzeiten.<\/div> <!-- description --><\/div><!-- porto-sicon-box -->[vc_empty_space height=&#8220;30px&#8220; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Warum sollten Sie sich f\u00fcr den AKT Go f\u00fcr Ihr Labor entscheiden?&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1775987746435{margin-bottom: 1.8rem !important;}&#8220; css_params=&#8220;&#8220;][vc_column_text css=&#8220;&#8220; css_params=&#8220;&#8220; el_class=&#8220;mb-3&#8243;]Das AKTA go macht die Proteinreinigung zu einem reibungslosen Routinevorgang. Trotz seiner kompakten Bauweise geht die Pr\u00e4zision der Gradienten in keiner Weise verloren, sodass bei jedem Durchlauf Fraktionen von hoher Reinheit gew\u00e4hrleistet sind.[\/vc_column_text]<div class=\"porto-sicon-box  vc_custom_1775051069407  wpb_custom_a0a370c8295ee40fc7556ca4643d7f66 style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Bew\u00e4hrte Zuverl\u00e4ssigkeit<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"\">Profitieren Sie von 30 Jahren Fachkompetenz im Bereich der Wasseraufbereitung.<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775051077374  wpb_custom_a0a370c8295ee40fc7556ca4643d7f66 style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Platzersparnis<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"\">Schaffen Sie Platz auf Ihrem Labortisch, ohne dabei auf Funktionalit\u00e4t verzichten zu m\u00fcssen.<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775051088147  wpb_custom_a0a370c8295ee40fc7556ca4643d7f66 style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Skalierbarkeit<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"\">Kompatibel mit zahlreichen optionalen Zubeh\u00f6rteilen (Fraktionssammler, zus\u00e4tzliche Ventile).<\/div> <!-- description --><\/div><!-- porto-sicon-box -->[\/vc_column][\/vc_row][vc_row full_width_css=&#8220;stretch_row_css&#8220; css=&#8220;.vc_custom_1775047134521{padding-top: 3.5rem !important;padding-bottom: 3.5rem !important;background-color: #1895de !important;}&#8220; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220;][vc_column][vc_row_inner wrap_container=&#8220;yes&#8220; el_class=&#8220;mb-0&#8243; css_params=&#8220;&#8220;][vc_column_inner width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;BPM TechCare, Ihr zertifizierter AKTA Go-Experte in der Schweiz&#8220; font_container=&#8220;tag:h3|font_size:2.25rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; skin=&#8220;light&#8220; css=&#8220;.vc_custom_1775987766077{margin-bottom: 1.8rem !important;}&#8220; css_params=&#8220;&#8220;][vc_column_text css=&#8220;&#8220; text_color=&#8220;var(&#8211;porto-light-color)&#8220; css_params=&#8220;&#8220;]Optimieren Sie die Lebensdauer Ihres Chromatographiesystems mit unserem spezialisierten AKTA-Wartungsservice. Ob es sich um eine kritische Installation, eine gr\u00fcndliche vorbeugende Wartung oder eine schnelle St\u00f6rungsbehebung handelt \u2013 unser Team gew\u00e4hrleistet die Langlebigkeit und Leistungsf\u00e4higkeit Ihrer Cytiva-Ger\u00e4te.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;Wir \u00fcbernehmen die Wartung und Reparatur Ihrer AKTA go-Ger\u00e4te in der Schweiz&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; skin=&#8220;light&#8220; css=&#8220;.vc_custom_1775051345066{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_column_text css=&#8220;&#8220; text_color=&#8220;var(&#8211;porto-light-color)&#8220; css_params=&#8220;&#8220;]Das <b data-path-to-node=\"6\" data-index-in-node=\"11\">AKTA Go<\/b> -System ist das Herzst\u00fcck Ihrer Proteinreinigung im kleinen Ma\u00dfstab. Selbst ein geringf\u00fcgiger Ausfall kann wochenlange Forschungsarbeit zunichte machen. Mit Sitz in der Schweiz bieten wir Ihnen h\u00f6chste Reaktionsf\u00e4higkeit, um die Genauigkeit Ihrer Ergebnisse und die Konformit\u00e4t Ihrer Anlagen zu gew\u00e4hrleisten.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner el_class=&#8220;mb-5&#8243; css_params=&#8220;&#8220;][vc_column_inner width=&#8220;1\/2&#8243;]<div class=\"porto-sicon-box  vc_custom_1775051480995  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Vorbeugende Wartung<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Austausch der Dichtungss\u00e4tze und der Leitungsfilter sowie vollst\u00e4ndige \u00dcberpr\u00fcfung des Hydraulikkreislaufs.<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775051489525  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Qualifizierung und Konformit\u00e4t (IQ\/OQ)<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Umfassende Dokumentation f\u00fcr Ihre Qualit\u00e4tsaudits und -zertifizierungen.<\/div> <!-- description --><\/div><!-- porto-sicon-box -->[\/vc_column_inner][vc_column_inner width=&#8220;1\/2&#8243;]<div class=\"porto-sicon-box  vc_custom_1775988130257  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Notfallreparatur<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Schnelle Fehlerdiagnose und Austausch kritischer Komponenten (Einspritzventile, UV-Monitor, P9-B-Pumpe).<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775988171482  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">UNICORN-Software-Support<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Aktualisierung, Konfiguration von Methoden und Behebung von Fehlern.<\/div> <!-- description --><\/div><!-- porto-sicon-box -->[\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_cta h2=&#8220;Funktioniert Ihre Hardware nicht ordnungsgem\u00e4\u00df? Erhalten Sie eine Software-Fehlermeldung? &#8220; txt_align=&#8220;center&#8220; shape=&#8220;square&#8220; style=&#8220;custom&#8220; add_button=&#8220;right&#8220; btn_title=&#8220;Kostenvoranschlag, kostenlose Bestandsaufnahme&#8220; btn_style=&#8220;modern&#8220; btn_color=&#8220;default&#8220; btn_size=&#8220;lg&#8220; btn_align=&#8220;center&#8220; btn_skin=&#8220;light&#8220; css=&#8220;&#8220; custom_background=&#8220;#f2f2f2&#8243; custom_text=&#8220;#1895de&#8220; css_params=&#8220;&#8220; btn_link=&#8220;url:https%3A%2F%2Fwww.bpmtc.ch%2Fde%2Fkontakt%2F|title:Kontakt|&#8220;]Kontaktieren Sie uns noch heute, um einen Serviceeinsatz f\u00fcr Ihren AKTA Go zu vereinbaren[\/vc_cta][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner el_class=&#8220;mb-3&#8243; width=&#8220;1\/2&#8243; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Warum sollten Sie sich f\u00fcr unseren technischen Service in der Schweiz entscheiden?&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; skin=&#8220;light&#8220; css=&#8220;.vc_custom_1775051596704{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Sorgen Sie f\u00fcr die Zuverl\u00e4ssigkeit Ihrer Ger\u00e4te mit unserem spezialisierten Wartungsservice f\u00fcr AKTA-Systeme. Mit Sitz in der Schweiz bieten wir Ihnen technischen Support vor Ort, um die Genauigkeit Ihrer Ergebnisse und die Langlebigkeit Ihrer Ger\u00e4te zu gew\u00e4hrleisten. &#8220; font_container=&#8220;tag:p|text_align:left|line_height:1.8em&#8220; use_theme_fonts=&#8220;yes&#8220; skin=&#8220;light&#8220; letter_spacing=&#8220;-0.015em&#8220; css=&#8220;.vc_custom_1775987936928{margin-bottom: 2.7rem !important;}&#8220; css_params=&#8220;&#8220;]<div class=\"porto-sicon-box  vc_custom_1775051790468  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Services vor Ort<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Schneller Vor-Ort-Einsatz in Lausanne, Z\u00fcrich, Basel oder Genf<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775051811771  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Zertifizierte Originalteile<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Ausschlie\u00dfliche Verwendung zertifizierter Komponenten zur Aufrechterhaltung der Garantie<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775051828812  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">FPLC-Gutachten<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Spezialisten f\u00fcr Cytiva-Systeme (ehemals GE Healthcare)<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775051848320  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Ma\u00dfgeschneiderte Wartungsvertr\u00e4ge<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Einzelleistungen oder j\u00e4hrliche Wartungsvertr\u00e4ge<\/div> <!-- description --><\/div><!-- porto-sicon-box -->[\/vc_column_inner][vc_column_inner width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;Die Vorteile der vorbeugenden Wartung&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; skin=&#8220;light&#8220; css=&#8220;.vc_custom_1775051920047{margin-bottom: 1.8rem !important;}&#8220; css_params=&#8220;&#8220;][vc_column_text css=&#8220;&#8220; text_color=&#8220;var(&#8211;porto-light-color)&#8220; css_params=&#8220;&#8220;]Die sorgf\u00e4ltige Wartung Ihres AKTA-Systems beschr\u00e4nkt sich nicht nur darauf, Ausf\u00e4lle zu vermeiden. Sie ist eine strategische Investition f\u00fcr Ihr Labor:[\/vc_column_text]<div class=\"porto-sicon-box  vc_custom_1775051962413  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Vollst\u00e4ndige Reproduzierbarkeit<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Vermeiden Sie Schwankungen der Basislinie und Scheinspitzen, die durch Verschlei\u00df der Kapillaren oder Ventile verursacht werden<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1782733207534  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Kostensenkung<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Eine regelm\u00e4\u00dfige Wartung kostet 30 % weniger als eine umfangreiche Reparatur nach einem Systemausfall<\/div> <!-- description --><\/div><!-- porto-sicon-box --><div class=\"porto-sicon-box  vc_custom_1775052007915  wpb_custom_8aa769cba03b33869bd025567b7728ae style_1 default-icon flex-wrap\"><div class=\"porto-sicon-default\"><div class=\"porto-just-icon-wrapper porto-icon advanced\" style=\"color:var(--porto-secondary-color);background:#e7e7e7;width:36px;height:36px;line-height:36px;border-radius:500px;font-size:17px;\"><i class=\"fas fa-check\"><\/i><\/div><\/div><div class=\"porto-sicon-header\"><h3 class=\"porto-sicon-title\" style=\"\">Verl\u00e4ngerte Lebensdauer<\/h3><\/div> <!-- header --><div class=\"porto-sicon-description\" style=\"color:var(--porto-light-color);\">Ein gut gewartetes System kann \u00fcber 10 Jahre lang effizient funktionieren<\/div> <!-- description --><\/div><!-- porto-sicon-box -->[vc_column_text css=&#8220;&#8220; text_color=&#8220;var(&#8211;porto-light-color)&#8220; css_params=&#8220;&#8220;]Wir empfehlen eine umfassende Wartung alle 1.000 Betriebsstunden oder mindestens einmal j\u00e4hrlich, um eine Salzkristallbildung in den Pumpenk\u00f6pfen zu verhindern.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row wrap_container=&#8220;yes&#8220; content_placement=&#8220;middle&#8220; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220; el_class=&#8220;sticky-wrapper&#8220; css=&#8220;.vc_custom_1775054328053{padding-top: 2.5em !important;}&#8220;][vc_column width=&#8220;1\/2&#8243;]<div class=\"porto-animation mb-0\"  data-appear-animation=\"fadeInLeft\">[vc_single_image image=&#8220;6895&#8243; img_size=&#8220;full&#8220; css=&#8220;&#8220; css_params=&#8220;&#8220; el_class=&#8220;mb-0&#8243; img_width=&#8220;{&#8222;xl&#8222;:&#8222;&#8222;,&#8222;unit&#8222;:&#8222;&#8222;,&#8222;xs&#8222;:&#8222;&#8222;,&#8222;sm&#8222;:&#8222;&#8222;,&#8222;md&#8222;:&#8222;&#8222;,&#8222;lg&#8222;:&#8222;&#8222;}&#8220; img_mwidth=&#8220;{&#8222;xl&#8222;:&#8222;&#8222;,&#8222;unit&#8222;:&#8222;&#8222;,&#8222;xs&#8222;:&#8222;&#8222;,&#8222;sm&#8222;:&#8222;&#8222;,&#8222;md&#8222;:&#8222;&#8222;,&#8222;lg&#8222;:&#8222;&#8222;}&#8220; img_height=&#8220;{&#8222;xl&#8222;:&#8222;&#8222;,&#8222;unit&#8222;:&#8222;&#8222;,&#8222;xs&#8222;:&#8222;&#8222;,&#8222;sm&#8222;:&#8222;&#8222;,&#8222;md&#8222;:&#8222;&#8222;,&#8222;lg&#8222;:&#8222;&#8222;}&#8220;]<\/div><div class=\"porto-u-heading  wpb_custom_9d727af5b97de3a52882e3e899c2673c porto-u-ad87e2eaf3f9c495180fe0156ddf3eb0  vc_custom_1775053161514\" data-appear-animation=\"fadeInUp\" data-appear-animation-delay=\"200\"><div class=\"porto-u-main-heading\"><h2  >Unsere Antworten auf Ihre h\u00e4ufigsten Fragen<\/h2><\/div><style>.porto-u-ad87e2eaf3f9c495180fe0156ddf3eb0.porto-u-heading{text-align:left}<\/style><\/div>[vc_custom_heading text=&#8220;Die Wartung von Pr\u00e4zisionsger\u00e4ten wie dem AKTA go erfordert fundiertes Fachwissen und umfassende Kenntnisse der Laborprotokolle. Um Ihnen dabei zu helfen, eine maximale Produktivit\u00e4t aufrechtzuerhalten, haben unsere Ingenieure die von unseren Kunden in der Schweiz am h\u00e4ufigsten gestellten Fragen zusammengestellt.<br \/>Ganz gleich, ob Sie mit einem Druckfehler konfrontiert sind, eine IQ\/OQ-Qualifizierung ben\u00f6tigen oder Fragen zur UNICORN\u2122-Software haben \u2013 hier finden Sie die wichtigsten Antworten, um die Kontinuit\u00e4t Ihrer Reinigungsvorg\u00e4nge zu gew\u00e4hrleisten. &#8220; font_container=&#8220;tag:p|text_align:left|line_height:1.8em&#8220; use_theme_fonts=&#8220;yes&#8220; letter_spacing=&#8220;-0.015em&#8220; animation_delay=&#8220;400&#8243; css=&#8220;.vc_custom_1775053330154{margin-bottom: 1.2rem !important;}&#8220; css_params=&#8220;&#8220; animation_type=&#8220;fadeInUp&#8220;][\/vc_column][vc_column width=&#8220;1\/2&#8243; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220;]<div class=\"porto-faqs porto-faqsvghx wpb_content_element \">\r\n\t<div class=\"page-faqs clearfix wpb_custom_7fe7ddf8f1a240d6488c8a8c41279112\" id=\"porto_faqs_2kwo\">\r\n\r\n\t\t\r\n\t\t\r\n\t\t<div class=\"faq-row faqs-container\">\r\n\t\t\t\r\n<div class=\"faq akta-go post-6872 type-faq status-publish hentry faq_cat-akta-go\">\r\n\t<section class=\"toggle\">\r\n\t\t<label>Wie oft muss ein AKTA go gewartet werden?<\/label>\r\n\t\t<div class=\"toggle-content\">\r\n\t\t<h3 class=\"entry-title\" style=\"display: none;\">Wie oft muss ein AKTA go gewartet werden?<\/h3><span class=\"vcard\" style=\"display: none;\"><span class=\"fn\"><a href=\"https:\/\/www.bpmtc.ch\/de\/author\/mateoz\/\" rel=\"author\">mateoz<\/a><\/span><\/span><span class=\"updated\" style=\"display:none\">2026-07-27T15:24:22+02:00<\/span><p>[vc_row el_class=\"mb-0\" conditional_render=\"%5B%7B%22value_role%22%3A%22administrator%22%7D%5D\" css_params=\"\"][vc_column][vc_column_text css=\"\" css_params=\"\" el_class=\"mb-0\"]Um eine optimale Leistung zu gew\u00e4hrleisten und ungeplante Ausf\u00e4lle zu vermeiden, empfehlen wir eine vorbeugende Wartung einmal j\u00e4hrlich oder alle 1.000 Betriebsstunden. In der Schweiz bevorzugen Labore, die nach ISO- oder GMP-Standards arbeiten, h\u00e4ufig eine halbj\u00e4hrliche \u00dcberpr\u00fcfung, um die Konformit\u00e4t der Ergebnisse sicherzustellen.[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\r\n\t\t<\/div>\r\n\t<\/section>\r\n<\/div>\r\n\r\n<div class=\"faq akta-go post-6871 type-faq status-publish hentry faq_cat-akta-go\">\r\n\t<section class=\"toggle\">\r\n\t\t<label>Was umfasst das vorbeugende Wartungsset f\u00fcr AKTA go?<\/label>\r\n\t\t<div class=\"toggle-content\">\r\n\t\t<h3 class=\"entry-title\" style=\"display: none;\">Was umfasst das vorbeugende Wartungsset f\u00fcr AKTA go?<\/h3><span class=\"vcard\" style=\"display: none;\"><span class=\"fn\"><a href=\"https:\/\/www.bpmtc.ch\/de\/author\/mateoz\/\" rel=\"author\">mateoz<\/a><\/span><\/span><span class=\"updated\" style=\"display:none\">2026-07-27T15:24:22+02:00<\/span>[vc_row][vc_column][vc_column_text css=\"\" css_params=\"\" el_class=\"mb-0\"]Das Standard-Wartungsset umfasst den Austausch der Pumpenkopfdichtungen, der Leitungsfilter und gegebenenfalls der R\u00fcckschlagventile sowie die Reinigung der Zellen des UV-Monitors. Zudem \u00fcberpr\u00fcfen wir die Dichtheit der Einspritzventile sowie die Kalibrierung der Druck- und Leitf\u00e4higkeitssensoren.[\/vc_column_text][\/vc_column][\/vc_row]\t\t<\/div>\r\n\t<\/section>\r\n<\/div>\r\n\r\n<div class=\"faq akta-go post-6869 type-faq status-publish hentry faq_cat-akta-go\">\r\n\t<section class=\"toggle\">\r\n\t\t<label>Wie behebe ich einen Fehler wegen zu hohem Druck an meinem AKTA go-System?<\/label>\r\n\t\t<div class=\"toggle-content\">\r\n\t\t<h3 class=\"entry-title\" style=\"display: none;\">Wie behebe ich einen Fehler wegen zu hohem Druck an meinem AKTA go-System?<\/h3><span class=\"vcard\" style=\"display: none;\"><span class=\"fn\"><a href=\"https:\/\/www.bpmtc.ch\/de\/author\/mateoz\/\" rel=\"author\">mateoz<\/a><\/span><\/span><span class=\"updated\" style=\"display:none\">2026-07-27T15:24:22+02:00<\/span>[vc_row][vc_column][vc_column_text css=\"\" css_params=\"\" el_class=\"mb-0\"]Ein hoher Druck ist h\u00e4ufig auf einen verstopften Inline-Filter, eine verstopfte S\u00e4ule oder Salzablagerungen in den Kapillaren zur\u00fcckzuf\u00fchren.\r\n<ul>\r\n \t<li>Sofortma\u00dfnahme: Wechseln Sie den Leitungsfilter aus und sp\u00fclen Sie das System mit ultrareinem Wasser und 20 % Ethanol durch.<\/li>\r\n \t<li>Sollte das Problem weiterhin bestehen: Es wird empfohlen, die Ventile von einem Techniker intern \u00fcberpr\u00fcfen zu lassen, um eine Besch\u00e4digung der P9-B-Pumpe zu vermeiden.<\/li>\r\n<\/ul>\r\n[\/vc_column_text][\/vc_column][\/vc_row]\t\t<\/div>\r\n\t<\/section>\r\n<\/div>\r\n\r\n<div class=\"faq akta-go post-6867 type-faq status-publish hentry faq_cat-akta-go\">\r\n\t<section class=\"toggle\">\r\n\t\t<label>Bieten Sie IQ\/OQ-Zertifizierungen f\u00fcr Labore in der Schweiz an?<\/label>\r\n\t\t<div class=\"toggle-content\">\r\n\t\t<h3 class=\"entry-title\" style=\"display: none;\">Bieten Sie IQ\/OQ-Zertifizierungen f\u00fcr Labore in der Schweiz an?<\/h3><span class=\"vcard\" style=\"display: none;\"><span class=\"fn\"><a href=\"https:\/\/www.bpmtc.ch\/de\/author\/mateoz\/\" rel=\"author\">mateoz<\/a><\/span><\/span><span class=\"updated\" style=\"display:none\">2026-07-27T15:24:22+02:00<\/span>[vc_row][vc_column][vc_column_text css=\"\" css_params=\"\" el_class=\"mb-0\"]Ja, wir bieten umfassende Services im Bereich der Installationsqualifizierung (IQ) und der Betriebsqualifizierung (OQ) an. Diese Validierungsprotokolle sind f\u00fcr Pharma- und Biotechnologielabore in der Schweiz unerl\u00e4sslich, um die Anforderungen der Zulassungsbeh\u00f6rden (Swissmedic, FDA) zu erf\u00fcllen.[\/vc_column_text][\/vc_column][\/vc_row]\t\t<\/div>\r\n\t<\/section>\r\n<\/div>\r\n\r\n<div class=\"faq akta-go post-6765 type-faq status-publish hentry faq_cat-akta-go\">\r\n\t<section class=\"toggle\">\r\n\t\t<label>Umfasst der Reparaturservice auch die UNICORN-Software?<\/label>\r\n\t\t<div class=\"toggle-content\">\r\n\t\t<h3 class=\"entry-title\" style=\"display: none;\">Umfasst der Reparaturservice auch die UNICORN-Software?<\/h3><span class=\"vcard\" style=\"display: none;\"><span class=\"fn\"><a href=\"https:\/\/www.bpmtc.ch\/de\/author\/mateoz\/\" rel=\"author\">mateoz<\/a><\/span><\/span><span class=\"updated\" style=\"display:none\">2026-07-27T14:24:58+02:00<\/span>[vc_row][vc_column][vc_column_text css=\"\" css_params=\"\" el_class=\"mb-0\"]Absolument. Notre expertise ne s'arr\u00eate pas au mat\u00e9riel. Nous intervenons sur la configuration du logiciel UNICORN, la sauvegarde de vos m\u00e9thodes, la gestion de la base de donn\u00e9es et le d\u00e9pannage des erreurs de communication entre le PC et l'AKTA go.[\/vc_column_text][\/vc_column][\/vc_row]\t\t<\/div>\r\n\t<\/section>\r\n<\/div>\r\n\r\n<div class=\"faq akta-go post-6757 type-faq status-publish hentry faq_cat-akta-go\">\r\n\t<section class=\"toggle\">\r\n\t\t<label>Wie lange dauert es, bis eine dringende Reparatur in der Schweiz durchgef\u00fchrt wird?<\/label>\r\n\t\t<div class=\"toggle-content\">\r\n\t\t<h3 class=\"entry-title\" style=\"display: none;\">Wie lange dauert es, bis eine dringende Reparatur in der Schweiz durchgef\u00fchrt wird?<\/h3><span class=\"vcard\" style=\"display: none;\"><span class=\"fn\"><a href=\"https:\/\/www.bpmtc.ch\/de\/author\/mateoz\/\" rel=\"author\">mateoz<\/a><\/span><\/span><span class=\"updated\" style=\"display:none\">2026-07-27T14:24:58+02:00<\/span><p>[vc_row][vc_column][vc_column_text css=\"\" css_params=\"\" el_class=\"mb-0\"]Gr\u00e2ce \u00e0 notre pr\u00e9sence locale, nous intervenons g\u00e9n\u00e9ralement sous 24 \u00e0 48 heures ouvrables dans les principaux p\u00f4les biotechnologiques (Arc l\u00e9manique, B\u00e2le, Zurich). Nous disposons d'un stock de pi\u00e8ces d\u00e9tach\u00e9es critiques pour minimiser le temps d'arr\u00eat de votre purification.[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n\t\t<\/div>\r\n\t<\/section>\r\n<\/div>\r\n\r\n<div class=\"faq akta-go post-6864 type-faq status-publish hentry faq_cat-akta-go\">\r\n\t<section class=\"toggle\">\r\n\t\t<label>Warum ist meine UV-Basislinie auf meinem \u00c4KTA go instabil?<\/label>\r\n\t\t<div class=\"toggle-content\">\r\n\t\t<h3 class=\"entry-title\" style=\"display: none;\">Warum ist meine UV-Basislinie auf meinem \u00c4KTA go instabil?<\/h3><span class=\"vcard\" style=\"display: none;\"><span class=\"fn\"><a href=\"https:\/\/www.bpmtc.ch\/de\/author\/mateoz\/\" rel=\"author\">mateoz<\/a><\/span><\/span><span class=\"updated\" style=\"display:none\">2026-07-27T15:24:22+02:00<\/span>[vc_row][vc_column][vc_column_text css=\"\" css_params=\"\" el_class=\"mb-0\"]Eine instabile Basislinie kann durch Luftblasen in der UV-Zelle oder durch eine alternde Lampe verursacht werden. Stellen Sie sicher, dass Ihre Stempel ordnungsgem\u00e4\u00df entgast sind. Sollte das Problem trotz gr\u00fcndlicher Sp\u00fclung weiterhin bestehen, muss der UV-Monitor m\u00f6glicherweise kalibriert werden oder die LED-Lichtquelle ausgetauscht werden.[\/vc_column_text][\/vc_column][\/vc_row]\t\t<\/div>\r\n\t<\/section>\r\n<\/div>\r\n\t\t<\/div>\r\n\r\n\t\t\r\n\t<\/div>\r\n\r\n\t\r\n\t<\/div>[\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row wrap_container=&#8220;yes&#8220; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220;][vc_column width=&#8220;1\/2&#8243;][vc_single_image image=&#8220;6936&#8243; img_size=&#8220;full&#8220; css=&#8220;.vc_custom_1782740974152{padding-bottom: 25px !important;}&#8220; el_class=&#8220;mb-3&#8243; css_params=&#8220;&#8220; label=&#8220;&#8220;][\/vc_column][vc_column width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;AKTA Go \u2013 Kompaktes Fl\u00fcssigkeitschromatographiesystem&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1775987711482{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Das AKTA go\u2122 ist ein kompaktes Fl\u00fcssigkeitschromatographiesystem, das von Cytiva f\u00fcr Routinereinigungen im Labor entwickelt wurde. Mit einem Durchflussbereich von bis zu 25 ml\/min und einem Betriebsdruck von bis [&hellip;]<\/p>\n","protected":false},"featured_media":6941,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"portfolio_cat":[75,76],"portfolio_skills":[],"class_list":["post-6926","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","portfolio_cat-akta","portfolio_cat-cytiva"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>AKTA Go - BPM TECHCARE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AKTA Go - BPM TECHCARE\" \/>\n<meta property=\"og:description\" content=\"[vc_row wrap_container=&#8220;yes&#8220; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220;][vc_column width=&#8220;1\/2&#8243;][vc_single_image image=&#8220;6936&#8243; img_size=&#8220;full&#8220; css=&#8220;.vc_custom_1782740974152{padding-bottom: 25px !important;}&#8220; el_class=&#8220;mb-3&#8243; css_params=&#8220;&#8220; label=&#8220;&#8220;][\/vc_column][vc_column width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;AKTA Go \u2013 Kompaktes Fl\u00fcssigkeitschromatographiesystem&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1775987711482{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Das AKTA go\u2122 ist ein kompaktes Fl\u00fcssigkeitschromatographiesystem, das von Cytiva f\u00fcr Routinereinigungen im Labor entwickelt wurde. Mit einem Durchflussbereich von bis zu 25 ml\/min und einem Betriebsdruck von bis [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/\" \/>\n<meta property=\"og:site_name\" content=\"BPM TECHCARE\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-27T13:31:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"18\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/\",\"url\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/\",\"name\":\"AKTA Go - BPM TECHCARE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bpmtc.ch\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp\",\"datePublished\":\"2025-01-08T07:47:14+00:00\",\"dateModified\":\"2026-07-27T13:31:21+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.bpmtc.ch\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp\",\"contentUrl\":\"https:\\\/\\\/www.bpmtc.ch\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp\",\"width\":600,\"height\":600,\"caption\":\"\u00c4KTA Go von Cytiva, ein kompaktes FPLC-Fl\u00fcssigkeitschromatographiesystem zur automatisierten Proteinreinigung in Forschungs- und Biotechnologielabors.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels\\\/akta-go\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Materiels\",\"item\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/materiels-equipements\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"AKTA Go\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/\",\"name\":\"BPM TECHCARE\",\"description\":\"Votre expert maintenance, d\u00e9pannage, r\u00e9paration et assistance pour vos \u00e9quipements de laboratoire AKTA en Suisse\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/#organization\",\"name\":\"BPM TECHCARE\",\"url\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.bpmtc.ch\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Logo-1SD.png\",\"contentUrl\":\"https:\\\/\\\/www.bpmtc.ch\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Logo-1SD.png\",\"width\":501,\"height\":201,\"caption\":\"BPM TECHCARE\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bpmtc.ch\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AKTA Go - BPM TECHCARE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/","og_locale":"de_DE","og_type":"article","og_title":"AKTA Go - BPM TECHCARE","og_description":"[vc_row wrap_container=&#8220;yes&#8220; conditional_render=&#8220;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8220; css_params=&#8220;&#8220;][vc_column width=&#8220;1\/2&#8243;][vc_single_image image=&#8220;6936&#8243; img_size=&#8220;full&#8220; css=&#8220;.vc_custom_1782740974152{padding-bottom: 25px !important;}&#8220; el_class=&#8220;mb-3&#8243; css_params=&#8220;&#8220; label=&#8220;&#8220;][\/vc_column][vc_column width=&#8220;1\/2&#8243;][vc_custom_heading text=&#8220;AKTA Go \u2013 Kompaktes Fl\u00fcssigkeitschromatographiesystem&#8220; font_container=&#8220;tag:h3|font_size:1.75rem|text_align:left|line_height:1em&#8220; use_theme_fonts=&#8220;yes&#8220; font_weight=&#8220;600&#8243; css=&#8220;.vc_custom_1775987711482{margin-bottom: 1.5rem !important;}&#8220; css_params=&#8220;&#8220;][vc_custom_heading text=&#8220;Das AKTA go\u2122 ist ein kompaktes Fl\u00fcssigkeitschromatographiesystem, das von Cytiva f\u00fcr Routinereinigungen im Labor entwickelt wurde. Mit einem Durchflussbereich von bis zu 25 ml\/min und einem Betriebsdruck von bis [&hellip;]","og_url":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/","og_site_name":"BPM TECHCARE","article_modified_time":"2026-07-27T13:31:21+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"18\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/","url":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/","name":"AKTA Go - BPM TECHCARE","isPartOf":{"@id":"https:\/\/www.bpmtc.ch\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/#primaryimage"},"image":{"@id":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp","datePublished":"2025-01-08T07:47:14+00:00","dateModified":"2026-07-27T13:31:21+00:00","breadcrumb":{"@id":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/#primaryimage","url":"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp","contentUrl":"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2025\/01\/AKTA-Go-Maintenance-Reparation-Suisse-06.webp","width":600,"height":600,"caption":"\u00c4KTA Go von Cytiva, ein kompaktes FPLC-Fl\u00fcssigkeitschromatographiesystem zur automatisierten Proteinreinigung in Forschungs- und Biotechnologielabors."},{"@type":"BreadcrumbList","@id":"https:\/\/www.bpmtc.ch\/de\/materiels\/akta-go\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.bpmtc.ch\/de\/"},{"@type":"ListItem","position":2,"name":"Materiels","item":"https:\/\/www.bpmtc.ch\/de\/materiels-equipements\/"},{"@type":"ListItem","position":3,"name":"AKTA Go"}]},{"@type":"WebSite","@id":"https:\/\/www.bpmtc.ch\/de\/#website","url":"https:\/\/www.bpmtc.ch\/de\/","name":"BPM TECHCARE","description":"Votre expert maintenance, d\u00e9pannage, r\u00e9paration et assistance pour vos \u00e9quipements de laboratoire AKTA en Suisse","publisher":{"@id":"https:\/\/www.bpmtc.ch\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bpmtc.ch\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.bpmtc.ch\/de\/#organization","name":"BPM TECHCARE","url":"https:\/\/www.bpmtc.ch\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.bpmtc.ch\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2026\/03\/Logo-1SD.png","contentUrl":"https:\/\/www.bpmtc.ch\/wp-content\/uploads\/2026\/03\/Logo-1SD.png","width":501,"height":201,"caption":"BPM TECHCARE"},"image":{"@id":"https:\/\/www.bpmtc.ch\/de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/portfolio\/6926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/types\/portfolio"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/comments?post=6926"}],"version-history":[{"count":2,"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/portfolio\/6926\/revisions"}],"predecessor-version":[{"id":6956,"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/portfolio\/6926\/revisions\/6956"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/media\/6941"}],"wp:attachment":[{"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/media?parent=6926"}],"wp:term":[{"taxonomy":"portfolio_cat","embeddable":true,"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/portfolio_cat?post=6926"},{"taxonomy":"portfolio_skills","embeddable":true,"href":"https:\/\/www.bpmtc.ch\/de\/wp-json\/wp\/v2\/portfolio_skills?post=6926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}